Encore SP201-SA Manual de usuario Pagina 8

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 14
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 7
8 SP201-SA™ Installation Guide
E.2 Channel Configuration for R1 Signaling
What the terminal displays What you type What you are configuring
user> config r1 all
All R1 channels
Set 1/1 thru 2/31 out-of-service?
(y or n) : <current=n> n
Placement of channels 1–31 of
trunk 1 and (on the four-port
SP201-SA) channels 1–31 of
trunk 2 into service
Template # for default IAM ? :
(range 1 - 5) : <current=1> 1
Use of R1 IAM template 1
Template # for default ACM ? :
(range 1 - 5) : <current=1 1
Use of R1 ACM template 1
Include Feature Group D (caller ID/
ANI)? (y or n) : <current=n>
y (or n if caller ID is
not required)
Request for caller
identification
(The following four questions appear only if you
answered y to the previous question.)
Use 911-Operator Services Signaling
(y or n) : <current=n> n
No use of 911 support
Max nbr of ANI digits to send R1 (0 =
all) ? : (range 0 - 32) : <current=0> 0 (zero)
Support for ANI of any size
Are Information digits supported? (y
or n) : <current=n> n
No support of Information
digits
Separate Wink required for B-Party
Number? (y or n) : <current=n> n
No separate wink for B-Party
Require wink at end of selection?
(y or n) : <current=n> n
No wink required at end of
selection
Generate ringback tone for R1
originated calls? (y or n) :
<current=n> n
No ringback generated for
caller
user>
(Standard configuration for
R1 signaling has been
completed. If y
ou wish to
configure other parameters for
R1 signaling, refer to the
SP201-SA Customization and
Maintenance Guide
.)
Vista de pagina 7
1 2 3 4 5 6 7 8 9 10 11 12 13 14

Comentarios a estos manuales

Sin comentarios