Vista de pagina 24
Product Specification
LC370EUN
Ver. 1.0
6. Reliability
Table 13. ENVIRONMENT TEST CONDITION
Note : Before and after Reliability test, LCM should be operated with normal function.
No. Test Item Condition
1 High temperature storage test Ta= 60°C 240h
2 Low temperature storage test Ta= -20°C 240h
3 High temperature operation test Ta= 50°C 50%RH 240h
4 Low temperature operation test Ta= 0°C 240h
5
Vibration test
(non-operating)
Wave form : random
Vibration level : 1.0Grms
Bandwidth : 10-300Hz
Duration : X,Y,Z,
Each direction per 10 min
6
Shock test
(non-operating)
Shock level : 50Grms
Waveform : half sine wave, 11ms
Direction : ±X, ±Y, ±Z
One time each direction
7 Humidity condition Operation Ta= 40 °C ,90%RH
8
Altitude operating
storage / shipment
0 - 15,000 ft
0 - 40,000 ft
23/36